Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Emerg Infect Dis ; 29(7): 1386-1396, 2023 07.
Artículo en Inglés | MEDLINE | ID: covidwho-20237258

RESUMEN

Isolating and characterizing emerging SARS-CoV-2 variants is key to understanding virus pathogenesis. In this study, we isolated samples of the SARS-CoV-2 R.1 lineage, categorized as a variant under monitoring by the World Health Organization, and evaluated their sensitivity to neutralizing antibodies and type I interferons. We used convalescent serum samples from persons in Canada infected either with ancestral virus (wave 1) or the B.1.1.7 (Alpha) variant of concern (wave 3) for testing neutralization sensitivity. The R.1 isolates were potently neutralized by both the wave 1 and wave 3 convalescent serum samples, unlike the B.1.351 (Beta) variant of concern. Of note, the R.1 variant was significantly more resistant to type I interferons (IFN-α/ß) than was the ancestral isolate. Our study demonstrates that the R.1 variant retained sensitivity to neutralizing antibodies but evolved resistance to type I interferons. This critical driving force will influence the trajectory of the pandemic.


Asunto(s)
COVID-19 , Interferón Tipo I , Humanos , SARS-CoV-2/genética , Interferón Tipo I/genética , Anticuerpos Neutralizantes , Sueroterapia para COVID-19 , Canadá/epidemiología , Anticuerpos Antivirales , Glicoproteína de la Espiga del Coronavirus
2.
Infect Control Hosp Epidemiol ; 42(11): 1340-1344, 2021 11.
Artículo en Inglés | MEDLINE | ID: covidwho-1574695

RESUMEN

BACKGROUND: Widespread testing for severe acute respiratory coronavirus virus 2 (SARS-CoV-2) is necessary to curb the spread of coronavirus disease 2019 (COVID-19), but testing is undermined when the only option is a nasopharyngeal swab. Self-collected swab techniques can overcome many of the disadvantages of a nasopharyngeal swab, but they require evaluation. METHODS: Three self-collected non-nasopharyngeal swab techniques (saline gargle, oral swab and combined oral-anterior nasal swab) were compared to a nasopharyngeal swab for SARS-CoV-2 detection at multiple COVID-19 assessment centers in Toronto, Canada. The performance characteristics of each test were assessed. RESULTS: The adjusted sensitivity of the saline gargle was 0.90 (95% CI 0.86-0.94), the oral swab was 0.82 (95% CI, 0.72-0.89) and the combined oral-anterior nasal swab was 0.87 (95% CI, 0.77-0.93) compared to a nasopharyngeal swab, which demonstrated a sensitivity of ˜90% when all positive tests were the reference standard. The median cycle threshold values for the SARS-CoV-2 E-gene for concordant and discordant saline gargle specimens were 17 and 31 (P < .001), for the oral swabs these values were 17 and 28 (P < .001), and for oral-anterior nasal swabs these values were 18 and 31 (P = .007). CONCLUSIONS: Self-collected saline gargle and an oral-anterior nasal swab have a similar sensitivity to a nasopharyngeal swab for the detection of SARS-CoV-2. These alternative collection techniques are cheap and can eliminate barriers to testing, particularly in underserved populations.


Asunto(s)
COVID-19 , Pacientes Ambulatorios , Humanos , Nasofaringe , SARS-CoV-2 , Saliva , Manejo de Especímenes
3.
Viruses ; 12(11)2020 11 17.
Artículo en Inglés | MEDLINE | ID: covidwho-927860

RESUMEN

Widely available and easily accessible testing for COVID-19 is a cornerstone of pandemic containment strategies. Nasopharyngeal swabs (NPS) are the currently accepted standard for sample collection but are limited by their need for collection devices and sampling by trained healthcare professionals. The aim of this study was to compare the performance of saliva to NPS in an outpatient setting. This was a prospective study conducted at three centers, which compared the performance of saliva and NPS samples collected at the time of assessment center visit. Samples were tested by real-time reverse transcription polymerase chain reaction and sensitivity and overall agreement determined between saliva and NPS. Clinical data was abstracted by chart review for select study participants. Of the 432 paired samples, 46 were positive for SARS-CoV-2, with seven discordant observed between the two sample types (four individuals testing positive only by NPS and three by saliva only). The observed agreement was 98.4% (kappa coefficient 0.91) and a composite reference standard demonstrated sensitivity of 0.91 and 0.93 for saliva and NPS samples, respectively. On average, the Ct values obtained from saliva as compared to NPS were higher by 2.76. This study demonstrates that saliva performs comparably to NPS for the detection of SARS-CoV-2. Saliva was simple to collect, did not require transport media, and could be tested with equipment readily available at most laboratories. The use of saliva as an acceptable alternative to NPS could support the use of widespread surveillance testing for SARS-CoV-2.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19 , COVID-19/diagnóstico , Nasofaringe/virología , Pacientes Ambulatorios/estadística & datos numéricos , SARS-CoV-2/aislamiento & purificación , Saliva/virología , Adulto , Femenino , Humanos , Límite de Detección , Masculino , Persona de Mediana Edad , Ontario , Estudios Prospectivos , ARN Viral/genética , Sensibilidad y Especificidad , Manejo de Especímenes
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA